| Project |
|
|
|
Roof of a laboratory, TU Eindhoven
|
Hybrid |
Netherlands |
|
General information
| Location address |
Eindhoven |
| Location country |
Netherlands |
| Function of building |
Laboratories & research centres |
| Primary function of the tensile structure |
Daylight gains Rain protection Space defining elements Wind protection
|
| Degree of enclosure |
Fully enclosed structure |
| Climatic zone |
Temperate - cold winters and mild summers |
| Number of layers |
mono-layer |
| Short description of the project |
Membrane tensioned in a geodesic dome (steel bars, Adjustable Lattice Connector) |
|
|
Misc. project details
|
|
Duration of use
| Temporary or permanent structure |
Temporary |
|
|
Material of the cover
| Cable-net/Textile/Hybrid/Foil |
Hybrid |
| Material Fabric/Foil |
Polyester |
| Material coating |
PVC |
|
|
Main dimensions and form
| Covered surface (m2) |
3000 |
| Total length (m) |
52 |
| Total width (m) |
52 |
| Maximum height (m) |
15 |
| Maximum free span (m) |
52 |
| Form of a single element |
Anticlastic |
| Form of entire structure |
Synclastic |
|
|
Involved companies
|
|
Editor
|